![Nuheat Cable (240V) Nuheat Cable (240V)](https://cdn11.bigcommerce.com/s-uyix53vy84/images/stencil/500x659/products/1094/5040/nVent_NUHEAT_Cable_Product_Image_1__53209.1549318157.jpg?c=2)
nVent Nuheat Cable provides the most on-site flexibility.
Cable is a floor heating cable system that is configured on-site during installation. Cable kits come in 33 sizes. Choose the cable kit that is best suited for the size of room/area and configure on-site to provide floor heat in the desired areas of the room.
Benefits
![]() | On-site flexibilityCable is adjusted on-site to provide heat coverage where it is desired. Installers only need to know the approximate square footage of the area(s) that need to be heated. |
![]() | Flexible wire spacing and heat outputCable provides the installer the ability to adjust the wire spacing and heat output according to installation needs. |
![]() | Compatible with nVent Nuheat MembraneCable is compatible with Membrane; the integrated floor heating and uncoupling product from nVent Nuheat. |
![]() | Comprehensive selection of sizes to choose from.Cable is available in 33 sizes in both 120 & 240 volt which allows installers to choose the perfect sized kit for the area they wish to heat. |
| Available immediately! |
Installation
![]() | 1. Plan the heating cable installation before securing any part of the floor heating system to the subfloor. |
![]() | 2. Install the heating cable according to the Installation Layout Plan. |
![]() | 3. Install stabilizing cable guides to ensure the heating cable does not float during the self-leveling process. |
![]() | 4. Secure the floor-sensing probe. Route the thermostat probe up to the thermostat electrical box. |
![]() | 5. Prepare the subfloor using self-leveling compound/thinset mortar as per manufacturer's instructions. |
![]() | 6. Install tile/stone flooring. |
See our recommended list of materials for planning your project.
Note:
1. Cable resistance must be tested before, during and after installation to validate nVent Nuheat warranties.
2. All wiring connections should be completed by a certified electrician.
Technical
Material | Two single conductor Tefzel-coated resistance wires covered by a tin-plated copper braid and then coated with a durable copolymer (PVC) outer jacket |
Operating Voltage | 120 V and 240 V |
Power Output | 12 - 15 watts per square foot depending on spacing option chosen) |
Maximum Continuous Exposure Temperature | 194°F (90°C) |
Heating Cable | 2-wire, grounded, twisted air with PVC outer jacket |
Cold Lead | 2-wire, 16-18 AWG plus ground braid layer; PVC outer jacket, 10 ft (3m) length |
Downloads
![]() | Brochure |
![]() | Product Fact Sheet |
![]() | Data Sheet |
![]() | Installation Guide |